Calibration for Thermal Analysis Instruments

Differential Scanning Calorimetry (DSC )
Thermogravimetric Analysis (TGA)
Thermomechanical Analysis (TMA)
Dynamic Mechanical Analysis (DMA)

Take the stress-free route and meet your quality and regulatory requirements with METTLER TOLEDO's Thermal Analysis Calibration Services. 

Whether you need to calibrate single or multiple heating rates or require a dedicated, in-depth calibration of your TGA balance, our calibration and adjustment services ensure the accuracy of your equipment and provide professional documentary evidence for your audit.

800 METTLER (800 638 8537)
Call Service

Thermal Analysis Calibration
Compliance with Regulations and Standards
Compliance with Regulations and Standards
Fully Traceable and Audit-Ready Certificates
Fully Traceable and Audit-Ready Certificates
Accurate and Reliable Results
Accurate and Reliable Results
Certified Reference Materials
Certified Reference Materials
Globally-Harmonized Procedures
Globally-Harmonized Procedures
On Demand Webinar: Thermal analysis service

Webinar – Service for Thermal Analysis Instrumentation

Find out how the correct care will extend the lifetime of your device. We explain how to maintain ac...

Validation in thermal analysis

Webinar – Validation in Thermal Analysis

Validation in thermal analysis demonstrates fitness for purpose of a proposed analytical method.

Thermal analysis service with METTLER TOLEDO provides the best equipment care.

Videos: Thermal Analysis Service

Watch the videos and find out how the correct care of your equipment reduces downtime and increases...

Datasheet: ACC Calibration Datasheet for TGA Microbalances

Datasheet: ACC Calibration Datasheet for TGA Microbalances

ACC quantifies the performance of your TGA micro- or ultra-microbalance and determines the measureme...

Datasheet: Thermal Analysis Calibration Service

Datasheet: Thermal Analysis Calibration Service

Benefit from our unique calibration and adjustment services for your thermal analysis instrumentatio...

Expert calibration and adjustment guide for thermal analysis.

Calibration and Adjustment for Thermal Analysis

Discover expert calibration and adjustment techniques for thermal analysis. Download our free guide...

What is the difference between Thermal Analysis Standard and Expert Calibration?

Standard CalibrationExpert Calibration

Single heating rate per substance

Sample temperature

Additional parameter

- DSC: heat flow

- TGA: mass

- TGA/DSC: mass/heat flow

- TMA: length/force

- DMA: displacement/force

Three heating rates per substance

Includes all Standard Calibration features

Sample temperature

Tau lag correction

Ideal solution for DSC and TGA

MT-approved SOPs and standardized certificates are provided for all calibrations.


See above for more details.

What is a tau-lag and a tau-lag correction?

During a Tau lag: 

  • As a sample is heated, there is a delay between the furnace temperature and the sample temperature
  • The sample temperature "lags behind" the furnace temperature
  • The amount of tau lag depends on the temperature

During a Tau lag correction:

  • An algorithm in STARe software calculates the time lag
  • It corrects for the delay between the furnace temperature and the sample temperature
  • After a correction, the measured thermal events will always have an identical temperature regardless of the heating rate

Thermal Analysis Tau Lag