The InPro 6860i/12/120/mA/HD is an optical dissolved oxygen sensor with a mechanically modified hydrophilic surface. Combined with its tilted design, it prevents bubble accumulation, creating a highly stable measurement signal.
الرجاء وصف مشروعك. /content/int/ar/home/products/Process-Analytics/DO-CO2-ozone-sensor/dissolved-oxygen-meter/optical-dissolved-oxygen-sensor/inpro6860i-hd-120-ma.fb.1.c.11.html
The angled tip and hydrophilic surface prevent bubble formation. This eliminates noise for improved production efficiency and process control.
For Digital & Analog Bioreactors
This anti-bubble DO sensor has digital (MODBUS, RS-485) and analog (mA) output signals for compatibility with benchtop bioreactors and transmitters.
Sterilizable and Autoclavable
The InPro 6860i/12/120/mA/HD provides fast, precise oxygen measurement, even after repeated autoclaving and sterilization cycles up to 140° C.
Stable, Reproducible Yields
Achieving consistent batches and product quality requires reliable oxygen measurement. The hydrophilic surface finish and tilted tip of the oxygen sensor prevent measurement interference from bubble accumulation that can affect yield and product quality.
Hygienic and Durable Design
Avoiding biofouling and ensure a stable signal with the PTFE coating of the OptoCap™ oxygen-sensing element. This ensures that the InPro6860i/12/120/mA/HD has the durability to withstand multiple autoclaving and standard CIP / SIP cycles.
Uncompromising Reliability
This optical DO sensor offers the benefits and predictive diagnostics of Intelligent Sensor Management. Achieve faster start up with Plug and Measure technology. Increased system availability is provided by maintaining a stock of pre-calibrated sensors.
Exceptional Performance
The 120mm InPro6860i/12/120/mA/HD reduces both handling time and running costs due to lower calibration and maintenance needs. This performance is achieved by an electrolyte-free, one-piece replacement part that is monitored by predictive diagnostics.
Continuous dissolved oxygen (DO) measurement is critical during fermentation and cell culture. The InPro 6860 i HD Anti-Bubble™ Oxygen Sensor is mecha...
This white paper provides educational content and shares practical expertise on corrosion and corrosion reduction in the chemical industry. It explain...
This case study describes how Ajinomoto needed more dependable pH and DO sensors, plus less sensor maintenance, they turned to METTLER TOLEDO. Now, in...
Novozymes is the world leader in the production of enzymes and has a global market share of more than 30%. Read in the case study how for Novozymes, o...
The M100 Sensor Mount (SM) is a single-channel transmitter for connecting ISM optical dissolved oxygen sensors to a biocontroller. The Bluetooth 4.0 interface is compatible with the PC-based and mobile versions of iSense software.